Studer Innotec
btn-menu
« Back

XTS 1400-48

With its seemingly limitless programmable functions, the XTS offers unequalled flexibility compared to other products on the market.

The inverter/charger has a continuous power rating of 750VA (900*) up to an ambient temperature of 40°C. In addition, it has a 30 minute power rating of 1200VA (1400*), and can deliver 2.8kVA for up to 5 secondsThanks to this very high surge power capacity, it can supply without worries loads with a high start-up current.

Additional power with the ECF-01 fan module, as an option.

The XTS offers a high degree of protection thanks to its IP54 housing and electronic protection against reverse polarity

The battery charge current can be adjusted between 0 and 12Adc. The factory default settings include a battery charge curve best suited for lead acid batteries with gelled electrolyte (GEL). This battery charge curve can be easily adapted to other types of batteries including OPzSNiFeLithium and Redox Flow, to name but a few.

The transfer system is active when an AC power source (generatorpublic gridshore power…) is available at the AC input of the Xtender. The transition between inverter and transfer mode is achieved without any power cut and allows up to 16Aac of current to pass through to the loadsSimilarly, the transition between transfer and inverter mode is extremely fast (max 15ms), which makes the Xtender suitable for many UPS (uninterruptable power supplyapplications

The Smart-Boost function allows the Xtender to assist the AC source via the inverter functionThis way, the currents from both sources (AC-in and inverter) are combined to deliver the energy required by big loads if the loads are more than the AC source can supply

The injection function allows the Xtender to send energy to the gridThis function is especially useful in energy storage systems where either the excess energy is injected to the grid, or a specific current is injected at a specific time of the day.

The ARM-02 accessory is a DIN rail module with two auxiliary contactsWhen connected to the XTS, it allows for all programming possibilities of the Xtender.

The RCM-10 accessory offers a remote entry to control the inverter externally

The Xtender has two auxiliary contactsconfigured by default for the automatic start of a generator and the alarm function.

In addition, the Xtender can be equipped with a remote entrywhich can be used to change functions or control the system externally.

Monitoring and control onsite or remotely is possible with the RCC-02/03 remote control or with the LAN, GSM or SMS interfacesDetailed information on all Xtender accessories can be found on the corresponding section of the website.

The Xtender communication bus is shared with the MPPT solar charge controllers of the VarioTrack and VarioString seriesInverters and charge controllers are synchronized to ensure an optimum charge of the battery and use of available energy.

Technical data